WINDOWS
WINDOWS

More than meets the eye

What is a space all about? Atmosphere, people that inhabit and use it, the feeling of belonging? Is it about boundaries? Separating what is inside from what is outside? Space is all about you. What you consider important. We create the frame that shapes your vision, keeps it safe and makes it beautiful.

Technologies

ELVIAL's steps to perfection. A key factor in the rapid growth of ELVIAL has been its ongoing investment of substantial capital innovative ideas and the application of state-of-the-art technologies and totally vertical profile and system processing and production.
ELVIAL I² TECHNOLOGY
ELVIAL PRE-ANODIZING 2IN1
ELVIAL I² TECHNOLOGY
ELVIAL I² TECHNOLOGY

Window Systems

ICONIC W77 AI² CE ICONIC W77 AI² ML ICONIC W77BS AI² CE ICONIC W77BS AI² ML
ICONIC W77 AI² CE ICONIC W77 AI² ML ICONIC W77BS AI² CE ICONIC W77BS AI² ML
DESIGN
- - - -
System Depth mm 77 77 77 77
Min Face Height Frame-Sash mm 89 89 66 66
Min Face Height Threshold-Sash mm 79 56 56
Min Face Width Middle Mullion mm 154 154 107 78
Design Minimal Design
Linear Design
Minimal Design
Linear Design
Minimal Design
Linear Design
Minimal Design
Linear Design
PROPERTIES
- - - -
Max Sash Height mm 2.800 2.800 2.500 2.500
Max Sash Width mm 1.400 1.400 1.400 1.400
Max Sash Weight kg 180 180 130 130
Max Glass Thickness mm 70 70 46 or 32 46 or 32
Mechanism Type Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Surface Finishings All All All All
PERFORMANCE
- - - -
Uf Value (≥) W/m²K 0.74 0.74 1.0 1.0
Air Permeability Class 4 Class 4 Class 4 Class 4
Watertightness E1200 E1200 Ε1050 Ε1050
Resistance to Wind Load kN/m² C5/B5 C5/B5 C5/B5 C5/B5
Sound Reduction 50 50
Operating Forces
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(450 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, frame deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ICONIC W77ST AI²
ICONIC W77ST AI²
DESIGN
-
System Depth mm 77
Min Face Height Frame-Sash mm 68
Min Face Height Threshold-Sash mm
Min Face Width Middle Mullion mm 89
Design Minimal Design
Industrial Design
PROPERTIES
-
Max Sash Height mm 2.400
Max Sash Width mm 1.200
Max Sash Weight kg 150
Max Glass Thickness mm 56
Mechanism Type European groove
mechanism [CE]
Surface Finishings All
ESSENCE W67 HI² CE ESSENCE W67BS HI² CE ESSENCE W67BS HI² ML
ESSENCE W67 HI² CE ESSENCE W67BS HI² CE ESSENCE W67BS HI² ML
DESIGN
- - -
System Depth mm 67 67 67
Min Face Height Frame-Sash mm 89 66 66
Min Face Height Threshold-Sash mm 56
Min Face Width Middle Mullion mm 154 107 78
Design Linear Design Minimal Design
Linear Design
Minimal Design
Linear Design
PROPERTIES
- - -
Max Sash Height mm 2.800 2.500 2.500
Max Sash Width mm 1.400 1.400 1.400
Max Sash Weight kg 180 130 130
Max Glass Thickness mm 60 46 or 41 or 28 46 or 41 or 28
Mechanism Type European groove
mechanism [CE]
European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Surface Finishings All All All
PERFORMANCE
- - -
Uf Value (≥) W/m²K 1.1 1.2 1.2
Air Permeability Class 4 Class 4 Class 4
Watertightness E1350 E1050 E1050
Resistance to Wind Load kN/m² C5/B5 C5/B5 C5/B5
Sound Reduction 44 38 38
Operating Forces Class 1
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ESSENCE W67ST HI² CE ESSENCE W67ST HI² ML
ESSENCE W67ST HI² CE ESSENCE W67ST HI² ML
DESIGN
- -
System Depth mm 67 67
Min Face Height Frame-Sash mm 75.2 75
Min Face Height Threshold-Sash mm
Min Face Width Middle Mullion mm 112.7 113
Design ROUNDED Design [RD] LINEAR Design [LD]
PROPERTIES
- -
Max Sash Height mm 2.300 2.400
Max Sash Width mm 800 1.200
Max Sash Weight kg 80 150
Max Glass Thickness mm 46 46
Mechanism Type European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Surface Finishings All All
ELVIAL W59 SI² CE ELVIAL W59 SI² CE_RD ELVIAL W59 SI² ML ELVIAL W59 SI² ML_RD ELVIAL W60BS SI²
ELVIAL W59 SI² CE ELVIAL W59 SI² CE_RD ELVIAL W59 SI² ML ELVIAL W59 SI² ML_RD ELVIAL W60BS SI²
DESIGN
- - - - -
System Depth mm 59 69 59 69 60
Min Face Height Frame-Sash mm 94 94 94 94 69
Min Face Height Threshold-Sash mm 107 103 107 103
Min Face Width Middle Mullion mm 156 156 156 156 93
Design Linear Design [LD] Rounded Design [RD] LINEAR Design [LD] Rounded Design [RD] Minimal Design
Linear Design
PROPERTIES
- - - - -
Max Sash Height mm 2.300 2.300 2.300 2.300 2.500
Max Sash Width mm 1.000 1.000 1.000 1.000 1.000
Max Sash Weight kg 130 130 130 130 100
Max Glass Thickness mm 46 36 46 36 24
Mechanism Type European groove
mechanism [CE]
European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove mechanism [ML]
Surface Finishings All All All All All
PERFORMANCE
- - - - -
Uf Value (≥) W/m²K 1.8 2.5 1.8 2.5 2.5
Air Permeability Class 4 Class 4 Class 4 Class 4 Class 4
Watertightness E1650 E1650 E1650 E1650 E1050
Resistance to Wind Load kN/m² C5/B5 C5/B5 C5/B5 C5/B5 C5/B5
Sound Reduction 40 40
Operating Forces
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E900
(900 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
E1350
(1350 Pa)
E1500
(1500 Pa)
E1650
(1650 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ELVIAL W89 PHI² CE ELVIAL W89 PHI² ML
ELVIAL W89 PHI² CE ELVIAL W89 PHI² ML
DESIGN
- -
System Depth mm 89 89
Min Face Height Frame-Sash mm 89 89
Min Face Height Threshold-Sash mm
Min Face Width Middle Mullion mm 154 154
Design LINEAR Design [LD] LINEAR Design [LD]
PROPERTIES
- -
Max Sash Height mm 2.800 2.800
Max Sash Width mm 1.600 1600
Max Sash Weight kg 200 200
Max Glass Thickness mm 83 83
Mechanism Type European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Surface Finishings All All
PERFORMANCE
- -
Uf Value (≥) W/m²K 0.62 0.62
Air Permeability Class 4 Class 4
Watertightness E1050 E1050
Resistance to Wind Load kN/m² C4/B4 C4/B4
Sound Reduction
Operating Forces
ELVIAL W92 HI² AW
ELVIAL W92 HI² AW
DESIGN
-
System Depth mm 92
Min Face Height Frame-Sash mm 109
Min Face Height Threshold-Sash mm
Min Face Width Middle Mullion mm 164
Design LINEAR Design [LD]
PROPERTIES
-
Max Sash Height mm 2.400
Max Sash Width mm 1.600
Max Sash Weight kg 130
Max Glass Thickness mm 48
Mechanism Type Alu-Wood
mechanism [AW]
Surface Finishings All
PERFORMANCE
-
Uf Value (≥) W/m²K 1.1
Air Permeability Class 4
Watertightness 7A
Resistance to Wind Load kN/m² C4/B4
Sound Reduction
Operating Forces
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E900
(900 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
Elvial Facebook Instagram Twitter YouTube Pinterest Pinterest Google Plus LinkedIn Previous Next
espa espa